Odyssey Fc Western Blot Imaging System

  • Flexible Western blot imaging system
  • Near-infrared fluorescent, chemiluminescent imaging & DNA gel documentation
  • High Western blot accuracy with stable, reproducible signals over time
  • No Western blot signal saturation
  • Easy-to-use Western blot imaging system: capture a single image without changing camera settings

The Odyssey Fc Western Blot Imaging System is designed for labs that need both chemiluminescent and near-infrared fluorescent Western blot detection. The Odyssey Fc Western blot imager offers reproducible, quantitative Western blot data using NIR fluorescence Western blot detection as well as eliminatation of the darkroom for chemiluminescent Western blot imaging.

What our users say about the Odyssey FC Imager What our users say about the Odyssey FC Imager

More reproducible and accurate Western blot data

The Odyssey Fc Western blot imager exhibits a wide 6 logs linear dynamic range that gives you more reproducible results and a very deep Western blot data capacity. As opposed to many Western blot CCD imagers, the wide linear dynamic range of the Odyssey Fc will always accurately record strong signals so you never have to worry about signal saturation and loss of your Western blot data.

Image complete Western blot data

With the uniform laser illumination of the Odyssey Fc Western Blot Imaging System you capture uniform, low-background images containing both strong and faint bands clearly in one single image, without adjusting the camera settings. The stable, reproducible near-infrared fluorescent signals over time ensure you with high accuracy of your Western blot data.

More reproducible data in more channels

The two channel near-infrared fluorescence of the Odyssey Fc Western blot imager offers you the possibility to see multiple targets on the same blot using secondary antibodies labeled with spectrally-distinct NIR fluorescent dyes.

In addition, you can also capture high-quality ECL Western blot images or document your DNA gels, all on the same imager, so you don't have to switch instruments.

Do you also want accurate & reproducible Western Blot data?

Journals like Science, Nature, Cell, and the Journal of Biological Chemistry are changing minimum content requirements and adopting rigorous Western Blot publishing guidelines.

Do yo also want more accurate and reproducible Western Blot data that is ready for publication? But are you not sure if you're Western Blot workflow meets the requirements needed? Find out more today!

More applications? See the Odyssey Clx

If you need an imager that can do more than image near-infrared and chemiluminescent Western Blots, than see the Odyssey Clx.

The Odyssey CLx can be used for more applications than quantitative and reproducible Western Blot analysis, such as EMSA assays, gel documentation, tissue section imaging, RNAi analysis and more. View the complete list of applications here.

Ordering information

Westburg offers this product in The Netherlands, Belgium, Luxembourg,
If you are not located in these countries please visit the LI-COR website to find your local distributor.
Cat no. Description
LI 2800-00 Odyssey FC Imaging System
LI 2800-510 Image Studio Software Odyssey Fc 25 users licence
LI 926-40020 Odyssey FC Imaging Tray (set of 5)